<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MicrobeHunter.com &#187; light</title>
	<atom:link href="http://www.microbehunter.com/tag/light/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.microbehunter.com</link>
	<description>of Microscopy, Microbes and More</description>
	<lastBuildDate>Wed, 01 Feb 2012 21:31:48 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Advantages of LED Microscopes</title>
		<link>http://www.microbehunter.com/2009/11/27/advantages-of-led-microscopes/</link>
		<comments>http://www.microbehunter.com/2009/11/27/advantages-of-led-microscopes/#comments</comments>
		<pubDate>Fri, 27 Nov 2009 12:33:10 +0000</pubDate>
		<dc:creator>Oliver</dc:creator>
				<category><![CDATA[Buying Advice]]></category>
		<category><![CDATA[led]]></category>
		<category><![CDATA[light]]></category>

		<guid isPermaLink="false">http://microscopy.okim.info/?page_id=1391</guid>
		<description><![CDATA[Light emitting diodes are a nearly ideal microscopic light source for several reasons. A school should seriously consider purchasing these. Long life span: LEDs have a life span of approximately 50 000-100 000 hours. A microscope which is in operation an unrealistic 12 hours per day would have a life span of 20 years+. Unlike [...]]]></description>
			<content:encoded><![CDATA[<p><div class='summary'>In recent years, high intensity light emitting diodes (LEDs) started to replace traditional light sources. LED microscopes offer significant advantages for microscopes used in education.</div> 
<div style='float:right; width:200px; margin-left:10px; margin-bottom:20px; margin-right:5px; clear:both;'>

<a href='http://www.microbehunter.com/wp/view-image?filename=http://www.microbehunter.com/wp/wp-content/uploads/2009/led1.jpg&alt=LED_light_of_a_stereo_microscope&caption=Bottom_LED_light_of_a_stereo_microscope._A_single_LED_is_sufficient._The_glass_stage_plate_has_been_removed._'>
<img src='http://www.microbehunter.com/wp/wp-content/uploads/2009/led1.jpg' alt='LED light of a stereo microscope' style='width:200px;'>
</a>
<div style='font-size:8pt; font-weight:bold; font-style:italic; padding-left:5px; padding-top:5px; margin:0px; line-height:12px;'>Bottom LED light of a stereo microscope. A single LED is sufficient. The glass stage plate has been removed.  <br></div>
</div>
 
<div style='float:right; width:200px; margin-left:10px; margin-bottom:20px; margin-right:5px; clear:both;'>

<a href='http://www.microbehunter.com/wp/view-image?filename=http://www.microbehunter.com/wp/wp-content/uploads/2009/led3.jpg&alt=LED_light_of_a_stereo_microscope&caption=Top_LED_light_of_a_stereo_microscope.'>
<img src='http://www.microbehunter.com/wp/wp-content/uploads/2009/led3.jpg' alt='LED light of a stereo microscope' style='width:200px;'>
</a>
<div style='font-size:8pt; font-weight:bold; font-style:italic; padding-left:5px; padding-top:5px; margin:0px; line-height:12px;'>Top LED light of a stereo microscope. <br></div>
</div>
 
<div style='float:right; width:200px; margin-left:10px; margin-bottom:20px; margin-right:5px; clear:both;'>

<a href='http://www.microbehunter.com/wp/view-image?filename=http://www.microbehunter.com/wp/wp-content/uploads/2009/led2.jpg&alt=Battery_compartment&caption=Rechargeable_batteries_deliver_an_operation_time_of_approx._50_hours_with_one_charge.'>
<img src='http://www.microbehunter.com/wp/wp-content/uploads/2009/led2.jpg' alt='Battery compartment' style='width:200px;'>
</a>
<div style='font-size:8pt; font-weight:bold; font-style:italic; padding-left:5px; padding-top:5px; margin:0px; line-height:12px;'>Rechargeable batteries deliver an operation time of approx. 50 hours with one charge. <br></div>
</div>
 Light emitting diodes are a nearly ideal microscopic light source for several reasons. A school should seriously consider purchasing these.</p>
<ul>
<li><strong>Long life span:</strong> LEDs have a life span of approximately 50 000-100 000 hours. A microscope which is in operation an unrealistic 12 hours per day would have a life span of 20 years+. Unlike tungsten or halogen light bulbs, LED lamps do not need to be replaced and are practically maintenance free.</li>
<li><strong>Low energy use:</strong> The electrical power is converted 80% into light, with nearly no heat production. The efficiency is therefore very high. This makes it possible to operate microscopes with batteries and without a power supply. LED microscopes can therefore also be used in classrooms in which the tables do not have an electrical power outlet. Incandescent light bulbs, in contrast, only convert 20% of the electrical energy to light, the rest is lost as heat.</li>
<li><strong>Not sensitive to movement:</strong> Hot tungsten or halogen light sources should not be moved during operation and when they are hot. Movement reduces the lifespan of the bulb becasue a hot filament breaks more easily when exposed to shock. LEDs are insensitive to movement. Bumping the microscope when the LEDs are on will have no detrimental effect on the LED.</li>
<li><strong>Can be switched on at full power:</strong> Incandescent light bulbs should not be switched on with the light intensity setting at maximum level. Rather, one should slowly increase the intensity after turning the light on. Sending maximum current through a cold bulb will reduce its lifespan. LEDs are insensitive in this respect. Sending a current through </li>
<li><strong>No color drift with age:</strong> LEDs do not significantly change their color or intensity with increasing age. Traditional incandescent light bulbs will shift towards the red end of the spectrum as they age. This is because over time a thin matallic layer will deposit on the inside of the glass bulb. A slight color shift can also be observed with LEDs, this is due to the aging of the resin of the LED. </li>
<li><strong>Nearly no heat produced: </strong>LEDs produce a cool light. LEDs pose no danger of overheating the specimen. This is important when observing water samples with live organisms. A heated specimen will drive out oxygen from the water sample which may possibly reduce movement of some (heterotrophic) organisms. </li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.microbehunter.com/2009/11/27/advantages-of-led-microscopes/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Changing the Lamp</title>
		<link>http://www.microbehunter.com/2008/12/20/changing-the-lamp/</link>
		<comments>http://www.microbehunter.com/2008/12/20/changing-the-lamp/#comments</comments>
		<pubDate>Sat, 20 Dec 2008 21:06:54 +0000</pubDate>
		<dc:creator>Oliver</dc:creator>
				<category><![CDATA[Maintenance]]></category>
		<category><![CDATA[lamp]]></category>
		<category><![CDATA[light]]></category>

		<guid isPermaLink="false">http://microscopy.okim.info/?p=400</guid>
		<description><![CDATA[This article explains how the lamp of a microscope is exchanged. It may not apply to all microscope types.]]></description>
			<content:encoded><![CDATA[<p> <div class='box'>Follow the instructions of the manufacturer when changing lamps. The presented method may not apply for all microscope types.</div> 
<div style='float:right; width:200px; margin-left:10px; margin-bottom:20px; margin-right:5px; clear:both;'>

<a href='http://www.microbehunter.com/wp/view-image?filename=http://www.microbehunter.com/wp/wp-content/uploads/2009/lamp1.jpg&alt=Exchanging_the_microscope_lamp&caption=Unplug_the_microscope._Open_the_bottom_of_the_microscope_to_reach_the_lamp._Pull_the_lamp_out_and_replace_it_with_a_new_one._Never_touch_a_new_lamp_with_your_fingers._Careful,_the_lamp_may_be_hot!'>
<img src='http://www.microbehunter.com/wp/wp-content/uploads/2009/lamp1.jpg' alt='Exchanging the microscope lamp' style='width:200px;'>
</a>
<div style='font-size:8pt; font-weight:bold; font-style:italic; padding-left:5px; padding-top:5px; margin:0px; line-height:12px;'>Unplug the microscope. Open the bottom of the microscope to reach the lamp. Pull the lamp out and replace it with a new one. Never touch a new lamp with your fingers. Careful, the lamp may be hot! <br></div>
</div>
 <div class='summary'>This article explains how the lamp of a microscope is exchanged. It may not apply to all microscope types.</div></p>
<p>A microscope lamp will last for many years. Tungsten lamps have the disadvantage that the color of the light will shift towards the red end of the spectrum and it may be necessary to exchange the lamp even before it burns out. Digital cameras are sensitive to the red end of the spectrum. This shift in color can easily be compensated by using a blue filter (&#8220;daylight filter&#8221;), but I have also seen older lamps which have a very pronounced red component.</p>
<p>When replacing a lamp, follow the instructions of the manufacturer. The following instructions are for microscopes that have a lamp compartment accessible from the bottom.</p>
<ul>
<li>Disconnect the microscope from the mains. It may also be a good idea to wait some time for the transformer to lose its magnetism (danger of electroshock otherwise? I don&#8217;t know, never tried it out&#8230; Energy is stored in the magnetic field of the transformer.)</li>
<li>Turn the microscope to its side, taking care that the eyepieces do not fall out.</li>
<li>Open the lamp compartment on the bottom of the microscope. Flip out the lamp.</li>
<li>Remove the lamp and replace it with a new one. Do not touch the new lamp with your fingers, wear gloves or use a piece of cloth. Fat deposits will burn into the lamp and result in a darker image.</li>
<li>Close the lamp compartment.</li>
</ul>